Description
Keywords: ADR03
Why was the ADR03 reference removed from the System Monitor User Guide?
Solution
The ADR03 may not be sufficient to supply the required AIdd to the System Monitor.
Looking at figure 21 of the ADR data sheet (page 12):
http://www.analog.com/static/imported-files/data_sheets/ADR01_02_03_06.pdfYou can see that once the load current gets close to 10 mA at 25C the drop-out goes above 2V.
The 125C graph goes above 2V after about 5.5 mA.
Therefore, there is a temperature dependency on the exact value of the reference.
Therefore, the ADR03 was removed from UG192. The other two references mentioned in the User Guide are the REF3025 and MAX6043.